Arteche manufactures trip and lockout relays with a wide range of options to met each application requirements. Reliability an performance by default for. Installed in more than countries, Arteche relays are the best choice for applications such as trip high and medium voltage breakers, safety critical logics in. Instantaneous relays contacts change instantaneously from non-working position to working position when its coil is energized, coming back contacts to the.

Author: Magul Mak
Country: Namibia
Language: English (Spanish)
Genre: Environment
Published (Last): 22 November 2004
Pages: 136
PDF File Size: 12.38 Mb
ePub File Size: 8.17 Mb
ISBN: 474-5-54804-306-1
Downloads: 48838
Price: Free* [*Free Regsitration Required]
Uploader: Mugis

TMS/Arteche Latching Auxiliary Relay

Trip and lockout relays Trip relays with 2 stable positions for the output contacts. The correct state of the circuit is showed with a green LED on the front plate of the relay. The contacts return to the rest position when the coil is no longer energized.

Auxiliary supply circuit supervision relays Auxiliary relay with four changeover contacts, aimed to supervise the failure of trip supply. In order to avoid faulty alarms due to instantaneous supply voltage dips, the drop off time of the relay is delayed over ms so those non-permanent failures of trip supply would not be considered.

  ANATOMIA CON ORIENTACION CLINICA MOORE PDF

Depending on which coil is energized, the contacts will change from one position to the other.

It uses reference signal from GPS Global Positioning System and features wide variety of outputs and time coding standards. Trip relays Instantaneous trip relays, whose contacts change instantaneously from the rest position to the working position when the coil is energized.

ARTECHE, Spain

Connecting the relay across the trip circuit supply, the equipment is normally energized. Instantaneous trip relays, whose contacts change instantaneously from the rest position to the working gelays when the coil is energized.

Trip circuit supervision relays For single phase or three phase circuit breakers. This range includes relay with 4 and 8 contacts, with operating times below 8 ms or 10 ms, depending on the model, and possibility of manual reset.

This range includes relays with 2, 4 relayz 8 contacts, with operating times from 3 ms to 8 ms, depending on the model.

For single phase or three phase circuit breakers. Through a artehe supervision current the whole circuit is supervised, in both positions of the circuit breaker opened or closed. The output contacts change its position if the relay detects a failure in the continuity of the circuit. Auxiliary relay with four changeover contacts, aimed to supervise the failure of trip supply. Trip relays with 2 stable positions for the output contacts. Faults will occur when the trip voltage is lost, so the relay drops off in those cases, providing the related signs and alarms.