IEEE 43-2013 PDF

IEEE Recommended Practice For Testing Insulation Resistance Of Electric Machinery Defines a recommended procedure for measuring insulation. The Institute of Electrical and Electronics Engineers (IEEE) standard for insulation resistance testing of motor and generator windings that was published in Content Description. Revision Standard – Active. The dc voltage tests procedures for the measurement of the insulation resistance and polarization index of.

Author: Kajir Tygole
Country: Canada
Language: English (Spanish)
Genre: History
Published (Last): 6 August 2013
Pages: 52
PDF File Size: 2.7 Mb
ePub File Size: 16.78 Mb
ISBN: 996-4-83485-319-8
Downloads: 98912
Price: Free* [*Free Regsitration Required]
Uploader: Tojajora

What’s new in the IEEE 43 insulation resistance testing standard? | EASA

It is not possible to cover all safety aspects in this recommended practice and test personnel should consult. The ground insulation certainly can be weak with conduction current flowing through ieeee insulation to ground, but this is often dwarfed by the surface currents. There were no books found for the applied search filters. I G — Conductance current: To find out if ieee leakage current is mainly a current or also contains the more damaging conductance current through the volume of the insulation to ground, one must do a step voltage test or ramp test to a test voltage one is comfortable with given the level of megohms measured.

FORMAT Single User Subscription Site License Subscription BOOKS All Books PACKAGES All Packages EDITION to PUBLISHER.

From this formula, ieee is very clear that the insulation properties drop precipitously as the temperature rises, and we all know what happens to over-heated motors.

  FORMULARZ SD-Z1 PDF

No items in cart. Note that the effects of moisture contamination on a healthy winding should ieeee preclude obtaining acceptable readings. Clause 1 and Clause See information below on minimum megohm levels.

Are you sure you want to empty the cart? There are ieee temperature compensation formulas, and ieee one above may be the most conservative. The quotient of the insulation resistance at time t 2 divided by the insulation resistance at iwee t 1.

Get a Quote Careers Exhibitions. Get a Quote Careers Exhibitions. Modern types of filmcoated wire, as well as epoxy-mica or polyester-mica insulated stator windings, may approach a constant value of insulation resistance in 4 min or less. Register for a trial account. Search book title Enter keywords for book title search.

IEEE 43-2013 PDF

In particular, this standard describes typical insulation problems detected ieee the insulation resistance test. Insulation Resistance IR is maybe the most common motor test.

IEEE is led by a diverse body of elected and appointed volunteer members.

Not Logged In Member?: For large machines with high capacitance, the inrush current can be high. The association is chartered under this name and it is the full legal name. Users will often go directly to a Hipot ieee Print 1 2 3 4 5 page sstarting from page current page.

Usually, for clean and dry rotating machine insulation, the insulation resistance between about 30 s and a few minutes is primarily determined by the absorption current. Most insulation testers will do this automatically if the winding temperature is entered in the tester. The strategic plan of IEEE is driven by an envisioned future that realizes the full potential of the role IEEE plays in advancing technology for humanity. For test voltages V and above, the lead between the test set and the winding must be appropriately insulated and spaced from otherwise, surface leakage currents and corona loss may introduce errors in the test data.

  BA3920 DATASHEET PDF

By definition, the insulation resistance is the quotient of the applied direct voltage across the insulation divided by the total resultant current at a given time.

Enter your account email address to request a password reset: After the applied direct voltage is removed, a suitable discharge circuit should be provided see Clause 4. C, and taken at a specified time t from start of voltage application. It also alerts the operator to a catastrophic connection from the windings to ground in the DUT. I T — Total current: The measured insulation resistance will usually rapidly increase when the voltage is first applied, and then gradually approach a relatively constant value as time elapses see Figure 4.

All others, please contact us at info madcad. This current is usually zero if the motor is new or undamaged. See Annex A for the use of other values.

What is a standard? The IEEE Brand Identity Toolkit explains the basic usage rules for all corporate identity elements and how to utilize them to create a powerful and consistent communications pieces.